Mfr Part # | RFQ | Series | Packaging | Product Status | Type | Form | Number of Poles | Voltage - Continuous Operating (Max) (MCOV) | Current - Discharge (Nom) (8/20µS) | Current - Discharge (Max) (8/20µS) | Current - Short Circuit Rating (SCRR) | Voltage - Protection Rating (VPR) | Voltage - Protection Level (VP) (2416) | Operating Temperature | Features | Mounting Type | Approval Agency | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
BSPM | Bulk | Active | Type 4 | Module Only | 1 | 75VAC, 100VDC | 10 kA | 40 kA | - | - | - | - | - | DIN Rail | CE, CSA, cURus, KEMA | |
|
|
SPD2 1P+1 | Bulk | Active | Type 1, Type 2 | Base + Module | 1 | 350V | 20 kA | 50 kA | 200 kA | 1 kV | 1.75 kV | -40°C ~ 80°C | Thermally Protected, Visual Life Indicator | DIN Rail | CE, cURus, UL, VDE | |
![]() |
|
SPD2 2P+0 | Bulk | Active | Type 1, Type 2 | Module Only | 2 | 750VAC | 20 kA | 35 kA | 200 kA | 2.5 kV | 3.4 kV | -40°C ~ 80°C | Remote Signaling Contacts, Thermally Protected | DIN Rail | cURus, UL, VDE | |
|
|
BSPH | Bulk | Active | Type 3 | Base + Module | 2 | 30VAC | 1 kA | 2 kA | 6 kA | - | 630 V | -40°C ~ 80°C | Remote Signaling Contacts | DIN Rail | CE, KEMA-KEUR | |
|
|
SPD2 3P+0 | Bulk | Active | Type 1, Type 2 | Base + Module | 3 | 150V | 20 kA | 50 kA | 200 kA | 600 V | 1.25 kV | -40°C ~ 80°C | Thermally Protected, Visual Life Indicator | DIN Rail | CE, cURus, UL, VDE | |
|
|
SPD2 3P+0 | Bulk | Active | Type 1, Type 2 | Base + Module | 3 | 300V | 20 kA | 50 kA | 150 kA | 900 V | 1.5 kV | -40°C ~ 80°C | Thermally Protected, Visual Life Indicator | DIN Rail | CE, cURus, UL, VDE | |
|
|
SPD2 PV | Bulk | Active | Type 1, Type 2 | Module Only | 1 | 1.5kV | 20 kA | 40 kA | 65 kA | 4 kV | 4.8 kV | -40°C ~ 80°C | Thermally Protected, Visual Life Indicator | DIN Rail | CE, cURus, UL, VDE | |
|
|
BSPH | Bulk | Active | Type 3 | Base + Module | 2 | 60VAC | 1 kA | 2 kA | 6 kA | - | 730 V | -40°C ~ 80°C | Remote Signaling Contacts | DIN Rail | CE, KEMA-KEUR | |
![]() |
|
1210 | Bulk | Active | Type 2, Type 4 | Module Only | 2 | 420VAC | 20 kA | 100 kA | 100 kA | 1.2 kV | 1.8 kV | -50°C ~ 85°C | Remote Signaling Contacts, Thermally Protected | DIN Rail | CE, CSA, UL | |
|
|
SPD2 3P+0 | Bulk | Active | Type 1, Type 2 | Base + Module | 3 | 350V | 20 kA | 50 kA | 200 kA | 1 kV | 1.75 kV | -40°C ~ 80°C | Thermally Protected, Visual Life Indicator | DIN Rail | CE, cURus, UL, VDE | |
|
|
SPD2 3P+0 | Bulk | Active | Type 1, Type 2 | Base + Module | 3 | 480V | 20 kA | 50 kA | 200 kA | 1.5 kV | 2.3 kV | -40°C ~ 80°C | Thermally Protected, Visual Life Indicator | DIN Rail | CE, cURus, UL, VDE | |
|
|
Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | ||
|
|
Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | ||
|
|
Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | ||
![]() |
|
1420 | Bulk | Active | Type 2, Type 4 | Module Only | 3 | 1.2kVDC | 20 kA | - | - | - | 3.6 kV | -50°C ~ 85°C | Remote Signaling Contacts, Thermally Protected | DIN Rail | CE, CSA, UR | |
|
|
BSPH | Bulk | Active | Type 3, Type 4 | Base + Module | 2 | 150VAC | 2 kA | 4 kA | 6 kA | - | - | -40°C ~ 80°C | - | DIN Rail | CSA, KEMA, UL | |
![]() |
|
SPD2 1P+1 | Bulk | Active | Type 1, Type 2 | Base + Module | 2 | 305VAC | 40 kA | 65 kA | 100 kA | 1 kV | 1.5 kV | -40°C ~ 80°C | Remote Signaling Contacts, Thermally Protected | DIN Rail | CE, cURus, UL, VDE | |
|
|
Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | ||
|
|
Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | ||
|
|
SPD2 3P+0 | Bulk | Active | Type 1, Type 2 | Base + Module | 3 | 550V | 20 kA | 50 kA | 200 kA | 2 kV | 2.5 kV | -40°C ~ 80°C | Thermally Protected, Visual Life Indicator | DIN Rail | CE, cURus, UL, VDE |