PDF |
Mfr Part # |
RFQ |
Series |
Packaging |
Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|
|
|
FN 2070 |
Tray |
Active | Single Phase | Two Stage | - | 110V, 250V | - | - | 25 A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Threaded Post (M4) | 2mH |
|
|
|
N |
Bulk |
Active | Single Phase | Three Stage | - | 250V | - | - | 10 A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | 7.83mH |
|
|
|
FN 2070 |
Box |
Active | Single Phase | Two Stage | - | 110V, 250V | - | - | 36 A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Threaded Post (M4) | 1.23mH |
|
|
|
FN 2070 |
Tray |
Active | Single Phase | Two Stage | - | 110V, 250V | - | - | 36 A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Threaded Post (M4) | 1.23mH |
|
|
|
T |
Bulk |
Active | Single Phase | Two Stage | - | 250V | - | - | 20 A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | - |
|
|
|
HT |
Bulk |
Active | Single Phase | Two Stage | - | 250V | - | - | 15 A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | 9.5mH |
|
|
|
Q |
Bulk |
Active | Single Phase | Two Stage | - | 250V | - | - | 20 A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | 6mH |
|
|
|
FN 2412 |
Tray |
Active | Single Phase | Single Stage | - | 250V | - | - | 45 A | DC ~ 400Hz | Regenerative Motor Drive | CSA, ENEC, UR | -25°C ~ 100°C | DIN Rail | Terminal Block | - |
|
|
|
FN 3270 |
Tray |
Active | Three Phase (Delta) | Single Stage | - | 480V | 300 V | 520 V | 20 A | DC ~ 60Hz | Inverters, Power Drive Systems | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
|
|
FC |
Bulk |
Active | Single Phase | Two Stage | - | 250V | - | - | 16 A | 50/60Hz | Inverters, Power Drive Systems | UR | -10°C ~ 40°C | Chassis Mount | Terminal Block | - |
|
|
|
FN 2020 |
Tray |
Active | Single Phase | Single Stage | - | 250V | - | - | 60 A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Threaded Post (M6) | 1mH |
|
|
|
FN 3026 |
Tray |
Active | Three Phase (Delta) | Single Stage | - | - | 300 V | 520 V | 20 A | 60Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | DIN Rail | Terminal Block | - |
|
|
|
FN 350 |
Tray |
Active | Single Phase | Single Stage | - | 250V | - | - | 20 A | DC ~ 400Hz | Regenerative Motor Drive | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
|
|
FN 3270 |
Tray |
Active | Three Phase (Delta) | Single Stage | - | 480V | 300 V | 520 V | 35 A | DC ~ 60Hz | Inverters, Power Drive Systems | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
|
|
FN 3025 |
Tray |
Active | Three Phase (Delta) | Single Stage | - | - | 300 V | 520 V | 50 A | DC ~ 60Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
|
|
FN 3258 |
Tray |
Active | Three Phase (Delta) | Single Stage | - | - | 277 V | 480 V | 16 A | DC ~ 60Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
|
|
FC |
Bulk |
Active | Single Phase | Two Stage | - | 250V | - | - | 36 A | 50/60Hz | Inverters, Power Drive Systems | UR | -10°C ~ 40°C | Chassis Mount | Terminal Block | - |
|
|
|
FN 3258 |
Tray |
Active | Three Phase (Delta) | Single Stage | - | - | 277 V | 480 V | 30 A | DC ~ 60Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
|
|
FN 3256 |
Tray |
Active | Three Phase (Wye) | Single Stage | - | 480V | 300 V | 520 V | 36 A | DC ~ 60Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
|
|
FN 3258 |
Box |
Active | Three Phase (Delta) | Single Stage | - | - | 277 V | 480 V | 42 A | DC ~ 60Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |