Mfr Part # | RFQ | Series | Packaging | Product Status | Connector Type | Gender | Number of Positions | Size | Termination Style | Voltage Rating | Current Rating (Amps) | Contact Type | Operating Temperature | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
|
HC25, CHC, HTS | Bulk | Active | Insert without Contacts | Female | 4 | - | Crimp | 60V | - | HDP-22 | -20°C ~ 80°C | |
![]() |
|
HMN | Bulk | Active | Module without Contacts | Male | 25 | - | Crimp | 50V | 5A | CAM, DAM | -40°C ~ 125°C | |
![]() |
|
HMN | Bulk | Active | Module without Contacts | Male | 25 | - | Crimp | 50V | 5A | CAM, DAM | -40°C ~ 125°C | |
![]() |
|
HMC | Bulk | Active | Insert without Contacts | Male | 12 | - | - | 250V | 43A | Mini-Fit Jr 5558 | -55°C ~ 125°C | |
![]() |
|
HC25, CHC, HTS | Bulk | Active | Insert without Contacts | Male | 4 | - | Crimp | 60V | - | HDP-22 | -20°C ~ 80°C | |
![]() |
|
HN.D.8, HTS | Bulk | Active | Insert without Contacts | Male | 8+Ground | 1 | Crimp | 42V | 10A | HTS HN.D | -40°C ~ 125°C | |
![]() |
|
HMN | Bulk | Active | Module, D-Sub | Male | 9 | - | Crimp | 50V | 5A | CAM, DAM | -40°C ~ 125°C | |
![]() |
|
HMN | Bulk | Active | Module, D-Sub | Female | 9 | - | Crimp | 50V | 5A | CAF, DAF | -40°C ~ 125°C | |
![]() |
|
HD.64, HTS | Bulk | Active | Insert without Contacts | Female | 64+Ground | 8 | Crimp | 250V | 10A | HD.M | -40°C ~ 125°C | |
![]() |
|
KN01 | Tray | Active | Insert without Contacts | Female | 12 | L | Crimp | 250V | 23A | - | -20°C ~ 105°C | |
|
|
KN01 | Tray | Active | Insert without Contacts | Female | 18 | L | Crimp | 24V | 3A | - | -20°C ~ 105°C | |
|
|
KN01 | Tray | Active | Insert without Contacts | Female | 50 | L | Crimp | 24V | 1A | - | -20°C ~ 105°C | |
![]() |
|
KN01 | Tray | Active | Insert without Contacts | Male | 50 | L | Crimp | 24V | 1A | - | -20°C ~ 105°C | |
![]() |
|
Han® 1A | Bulk | Active | Insert without Contacts | Male | 3+Ground | 1A | Crimp | 400V | 16A | Han® D | -30°C ~ 90°C | |
![]() |
|
Han® 1A | Bulk | Active | Insert without Contacts | Male | 5+Ground | 1A | Crimp | 400V | 10A | Han® D | -30°C ~ 90°C | |
![]() |
|
Han® 1A | Bulk | Active | Insert without Contacts | Female | 3+Ground | 1A | Crimp | 400V | 16A | Han® D | -30°C ~ 90°C | |
![]() |
|
Han® 1A | Bulk | Active | Insert without Contacts | Female | 5+Ground | 1A | Crimp | 400V | 10A | Han® D | -30°C ~ 90°C | |
![]() |
|
Han® 1A | Bulk | Active | Insert without Contacts | Male | 3+Ground | 1A | Crimp | 400V | 10A | Han® D | -30°C ~ 90°C | |
![]() |
|
Han® 1A | Bulk | Active | Insert | Male | 2+Ground | 1A | Screw | 400V | 10A | - | -30°C ~ 90°C | |
![]() |
|
Han® 1A | Bulk | Active | Insert | Male | 2+Ground | 1A | Screw | 400V | 10A | - | -30°C ~ 90°C |