Gas Sensors
820 Items
PDF Mfr Part # RFQ Series Packaging Product StatusTypeOxygen RangeAccuracyOutputOperating TemperatureVoltage - SupplyCurrent - Supply
T0007838-NA
T0007838-NA
BREEZE : CO2 SENSOR, WITH E-INK
TEKTELIC Communications Inc.
BREEZE Box ActiveCarbon Dioxide (CO2)-±10%I²C0°C ~ 60°C--
T5100-LED
T5100-LED
AIRESTAT, 1CH CO2/A TEMP, LED, U
Amphenol Advanced Sensors
T5100 Bulk ActiveCarbon Dioxide (CO2), Humidity, Temperature-±2%0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA0°C ~ 50°C18VAC ~ 30VAC, 18VDC ~ 42VDC-
T8100-GN
T8100-GN
VENTOSTAT, 1CH CO2/P TEMP, UWHT,
Amphenol Advanced Sensors
T8000 Bulk ActiveCarbon Dioxide (CO2), Humidity, Temperature-±2%0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA0°C ~ 50°C18VAC ~ 30VAC, 18VDC ~ 42VDC-
T8100-5V
T8100-5V
VENTOSTAT, 1CH CO2/P TEMP, 5V, U
Amphenol Advanced Sensors
T8000 Bulk ActiveCarbon Dioxide (CO2), Humidity, Temperature-±2%0 V ~ 5 V0°C ~ 50°C18VAC ~ 30VAC, 18VDC ~ 42VDC-
T8100-NS
T8100-NS
VENTOSTAT, 1CH CO2/P TEMP,NS, UW
Amphenol Advanced Sensors
T8000 Bulk ActiveCarbon Dioxide (CO2), Humidity, Temperature-±2%0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA0°C ~ 50°C18VAC ~ 30VAC, 18VDC ~ 42VDC-
T8100-B
T8100-B
VENTOSTAT, 1CH CO2/P TEMP, UBLK
Amphenol Advanced Sensors
T8000 Bulk ActiveCarbon Dioxide (CO2), Humidity, Temperature-±2%0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA0°C ~ 50°C18VAC ~ 30VAC, 18VDC ~ 42VDC-
PR52-33M
PR52-33M
PARTICULATE MATTER SENSOR
National Control Devices
PR52 Box ActiveAir Quality-±2%--25°C ~ 85°C--
T8200-D
T8200-D
CO2/TEMP SENS WALL MNT DUAL OUT
Amphenol Telaire
T8000 Bulk ActiveCarbon Dioxide (CO2)-±5%0 V ~ 5 V, 0 V ~ 10 V (Selectable)0°C ~ 50°C18 VAC ~ 30VAC RMS, 18 VDC ~ 42 VDC4 ~ 20mA
T8200-D-10P
T8200-D-10P
VENTOSTAT, 2CH CO2/P TEMP, DISPL
Amphenol Advanced Sensors
T8000 Bulk ActiveCarbon Dioxide (CO2), Humidity, Temperature-±2%0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA0°C ~ 50°C18VAC ~ 30VAC, 18VDC ~ 42VDC1A
T8100-H
T8100-H
VENTOSTAT, 1CH CO2/PA TEMP/RH, U
Amphenol Advanced Sensors
T8000 Bulk ActiveCarbon Dioxide (CO2), Humidity, Temperature-±2%0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA0°C ~ 50°C18VAC ~ 30VAC, 18VDC ~ 42VDC-
T8200-HD
T8200-HD
VENTOSTAT, 2CH CO2/PA TEMP/RH, D
Amphenol Advanced Sensors
T8000 Bulk ActiveCarbon Dioxide (CO2), Humidity, Temperature-±2%0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA0°C ~ 50°C18VAC ~ 30VAC, 18VDC ~ 42VDC1A
T5000
T5000
CO2 MONITOR
Comet America, LP
Box ActiveCarbon Dioxide (CO2)-±2%--30°C ~ 60°C9V ~ 30V-
D0221
D0221
2 CH. THERMOMETER NI1000/PT1000
Comet America, LP
Box Active--±0.3%--30°C ~ 65°C12V-
T5340
T5340
CO2 TRANSMITTER WITH RS232
Comet America, LP
Box ActiveCarbon Dioxide (CO2)-±2%RS232-30°C ~ 60°C9V ~ 30V-
T5240
T5240
CO2 TRANSMITTER WITH 0-10V
Comet America, LP
Box ActiveCarbon Dioxide (CO2)-±2%0 V ~ 10 V-30°C ~ 60°C15V ~ 30V-
T5140
T5140
CO2 TRANSMITTER WITH 4-20MA
Comet America, LP
Box ActiveCarbon Dioxide (CO2)-±2%4mA ~ 20mA-30°C ~ 60°C9V ~ 30V-
T5145
T5145
CO2 TRANSMITTER WITH 4-20MA
Comet America, LP
Box ActiveCarbon Dioxide (CO2)-±2%4mA ~ 20mA-30°C ~ 60°C9V ~ 30V-
T5245
T5245
CO2 TRANSMITTER WITH 0-10V
Comet America, LP
Box ActiveCarbon Dioxide (CO2)-±2%0 V ~ 10 V-30°C ~ 60°C15V ~ 30V-
T5440
T5440
CO2 TRANSMITTER WITH RS485
Comet America, LP
Box ActiveCarbon Dioxide (CO2)-±2%RS485-30°C ~ 60°C9V ~ 30V-
H5024
H5024
CO2 REGULATOR
Comet America, LP
Box ActiveCarbon Dioxide (CO2)-±2%--30°C ~ 60°C9V ~ 30V2A