Current Sensors
2599 Items
PDF Mfr Part # RFQ Series Packaging Product StatusFor MeasuringSensor TypeCurrent - SensingNumber of ChannelsOutputSensitivityFrequencyLinearityAccuracyVoltage - SupplyResponse TimeCurrent - Supply (Max)Operating TemperaturePolarizationMounting TypePackage / CaseSupplier Device Package
CASR 50-NP
CASR 50-NP
SENSOR CURRENT FLUX 50A AC/DC
LEM USA Inc.
CASR Tray ActiveAC/DCFlux Gate, Closed Loop50A1Ratiometric, Voltage12.5mV/A300kHz±1%±0.8%4.75V ~ 5.25V0.3µs20mA-40°C ~ 85°CBidirectionalThrough HoleModule-
LESR 50-NP
LESR 50-NP
SENSOR CURRENT HALL 50A UNIPOLAR
LEM USA Inc.
LESR Tray ActiveAC/DCHall Effect, Closed Loop50A1Ratiometric, Voltage12.5mV/A300kHz±0.1%±1.25%4.75V ~ 5.25V400ns51.3mA-40°C ~ 105°C (TA)BidirectionalThrough HoleModule-
HASS 50-S
HASS 50-S
SENSOR CURRENT HALL 50A AC/DC
LEM USA Inc.
HASS Tray ActiveAC/DCHall Effect, Open Loop50A1Ratiometric, Voltage-DC ~ 50kHz±0.5%±1%5V3µs19mA-40°C ~ 85°CBidirectionalThrough HoleModule-
HASS 100-S
HASS 100-S
SENSOR CURRENT HALL 100A AC/DC
LEM USA Inc.
HASS Tray ActiveAC/DCHall Effect, Open Loop100A1Ratiometric, Voltage-DC ~ 50kHz±0.5%±1%5V3µs19mA-40°C ~ 85°CBidirectionalConnectorModule-
HASS 200-S
HASS 200-S
SENSOR CURRENT HALL 200A AC/DC
LEM USA Inc.
HASS Tray ActiveAC/DCHall Effect, Open Loop200A1Ratiometric, Voltage-DC ~ 50kHz±0.5%±1%5V3µs19mA-40°C ~ 85°CBidirectionalThrough HoleModule-
L06P800S05
L06P800S05
SENSOR CURRENT HALL 800A AC/DC
Tamura
Bulk ActiveAC/DCHall Effect, Open Loop800A1Ratiometric, Voltage-DC ~ 100kHz±1%-5V5µs15mA-40°C ~ 85°CBidirectionalThrough HoleModule-
HO 50-S
HO 50-S
SENSOR CURRENT HALL 50A AC/DC
LEM USA Inc.
HO-S Tray ActiveAC/DCHall Effect, Open Loop50A1Ratiometric, Voltage-DC ~ 100kHz±0.75%±1%5V30µs15mA-40°C ~ 105°CBidirectionalChassis MountModule, Single Pass Through-
HASS 300-S
HASS 300-S
SENSOR CURRENT HALL 300A AC/DC
LEM USA Inc.
HASS Tray ActiveAC/DCHall Effect, Open Loop300A1Ratiometric, Voltage-DC ~ 50kHz±0.5%±1%5V3µs19mA-40°C ~ 85°CBidirectionalThrough HoleModule-
HASS 400-S
HASS 400-S
SENSOR CURRENT HALL 400A AC/DC
LEM USA Inc.
HASS Tray ActiveAC/DCHall Effect, Open Loop400A1Ratiometric, Voltage-DC ~ 50kHz±0.5%±1%5V3µs19mA-40°C ~ 85°CBidirectionalThrough HoleModule-
HASS 500-S
HASS 500-S
SENSOR CURRENT HALL 500A AC/DC
LEM USA Inc.
HASS Tray ActiveAC/DCHall Effect, Open Loop500A1Ratiometric, Voltage-DC ~ 50kHz±0.5%±1%5V3µs19mA-40°C ~ 85°CBidirectionalThrough HoleModule-
LAH 50-P
LAH 50-P
SENSOR CURRENT HALL 50A AC/DC
LEM USA Inc.
LAH Bulk ActiveAC/DCHall Effect, Closed Loop50A1Ratiometric, Current-DC ~ 200kHz±0.15%±0.25%±12V ~ 15V0.5µs35mA-25°C ~ 85°CBidirectionalThrough HoleModule-
LAH 100-P
LAH 100-P
SENSOR CURRENT HALL 100A AC/DC
LEM USA Inc.
LAH Bulk ActiveAC/DCHall Effect, Closed Loop100A1Ratiometric, Current-DC ~ 200kHz±0.15%±0.25%±12V ~ 15V0.5µs60mA-25°C ~ 85°CBidirectionalThrough HoleModule-
HAIS 100-P
HAIS 100-P
SENSOR CURRENT HALL 100A AC/DC
LEM USA Inc.
HAIS Tray ActiveAC/DCHall Effect, Open Loop100A1Ratiometric, Voltage-DC ~ 50kHz±0.5%±1%5V5µs19mA-40°C ~ 85°CBidirectionalThrough HoleModule-
HAIS 200-P
HAIS 200-P
SENSOR CURRENT HALL 200A AC/DC
LEM USA Inc.
HAIS Tray ActiveAC/DCHall Effect, Open Loop200A1Ratiometric, Voltage-DC ~ 50kHz±0.5%±1%5V5µs19mA-40°C ~ 85°CBidirectionalThrough HoleModule-
HAIS 100-TP
HAIS 100-TP
SENSOR CURRENT HALL 100A AC/DC
LEM USA Inc.
HAIS Tray ActiveAC/DCHall Effect, Open Loop100A1Ratiometric, Voltage-DC ~ 50kHz±0.5%±1%5V5µs19mA-40°C ~ 85°CBidirectionalThrough HoleModule-
HAS 50-S
HAS 50-S
SENSOR CURRENT HALL 50A AC/DC
LEM USA Inc.
HAS Tray ActiveAC/DCHall Effect, Open Loop50A1Ratiometric, Voltage-DC ~ 50kHz±1%±1%±15V3µs15mA-10°C ~ 80°CBidirectionalThrough HoleModule-
HAS 200-S
HAS 200-S
SENSOR CURRENT HALL 200A AC/DC
LEM USA Inc.
HAS Tray ActiveAC/DCHall Effect, Open Loop200A1Ratiometric, Voltage-DC ~ 50kHz±1%±1%±15V3µs15mA-10°C ~ 80°CBidirectionalThrough HoleModule-
HAS 300-S
HAS 300-S
SENSOR CURRENT HALL 300A AC/DC
LEM USA Inc.
HAS Tray ActiveAC/DCHall Effect, Open Loop300A1Ratiometric, Voltage-DC ~ 50kHz±1%±1%±15V3µs15mA-10°C ~ 80°CBidirectionalThrough HoleModule-
T60404N4646X931
T60404N4646X931
DIFFERENTIAL CURRENT SENSOR, 100
VACUUMSCHMELZE
Box ActiveAC/DCClosed Loop85A1Ratiometric, Voltage-DC ~ 8kHz±1%±1.5%4.75V ~ 5.25V40µs15mA-40°C ~ 85°C (TA)UnidirectionalThrough Hole14-DIP Module-
S27S300D15YM
S27S300D15YM
SENSOR CURRENT HALL 300A AC/DC
Tamura
Bulk ActiveAC/DCHall Effect, Closed Loop300A1Ratiometric, Current-DC ~ 100kHz±0.1%±0.4%±12V ~ 20V1µs20mA-40°C ~ 85°CBidirectionalPanel MountModule-