PDF |
Mfr Part # |
RFQ |
Series |
Packaging |
Product Status | Type | Number of Outputs | Voltage - Input | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Current - Output 1 | Current - Output 2 | Current - Output 3 | Current - Output 4 | Current - Output 5 | Current - Output 6 | Power (Watts) | Applications | Voltage - Isolation | Efficiency | Operating Temperature | Features | Mounting Type | Size / Dimension | Approval Agency | Standard Number |
|
|
|
ECE60 (60W) |
Box |
Active | Enclosed | 1 | 85 ~ 264 VAC | 9V | - | - | - | - | - | 6.67 A | - | - | - | - | - | 60W | ITE (Commercial) | 3 kV | 87% | -40°C ~ 70°C (With Derating) | DC Input Capable, Universal Input | Chassis Mount | 4.09" L x 1.57" W x 1.12" H (104.0mm x 40.0mm x 28.5mm) | - | 62368-1 |
|
|
|
Linear C |
Bulk |
Active | Linear | 1 | 100, 120, 220, 230, 240 VAC | 12V | - | - | - | - | - | 3.4 A | - | - | - | - | - | 41W | ITE (Commercial) | 3 kV | 55% | 0°C ~ 50°C | Adjustable Output, Remote Sense | Chassis Mount | 5.62" L x 4.87" W x 2.95" H (142.8mm x 123.7mm x 74.9mm) | - | - |
|
|
|
Linear AA |
Bulk |
Active | Linear | 2 | 100, 120, 220, 230, 240 VAC | 15V | -15V | - | - | - | - | 800 mA | 800 mA | - | - | - | - | 24W | ITE (Commercial) | 4.242 kV | 55% | 0°C ~ 50°C | Adjustable Output, Remote Sense | Chassis Mount | 6.50" L x 4.00" W x 2.10" H (165.1mm x 101.6mm x 53.3mm) | CE, CSA, UL | 60950-1; 62368-1 |
|
|
|
FSP500-50UCB (500W) |
Box |
Active | Enclosed | 5 | 90 ~ 264 VAC | 3.3V | 5V | 12V | -12V | -5V | -5V | 14 A | 16 A | 41 A | 300 mA | 100 mA | - | 622W | ITE (Commercial) | - | 80% | 0°C ~ 50°C | Standby Output, Universal Input | Chassis Mount | 7.48" L x 3.94" W x 1.59" H (190.0mm x 100.0mm x 40.5mm) | CB, CE, cULus, FCC, GS, TUV | 60950-1; 62368-1 |
|
|
|
GCS (180W) |
Box |
Active | Open Frame | 1 | 85 ~ 264 VAC | 15V | - | - | - | - | - | 10 A | - | - | - | - | - | 150W (180W Forced Air) | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 70°C (With Derating) | Adjustable Output, Standby Output, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.42" H (127.0mm x 76.2mm x 36.3mm) | CB, CE | 62368-1 |
|
|
|
VSBU-120 (120W) |
Box |
Not For New Designs | Open Frame | 1 | 90 ~ 260 VAC | 36V | - | - | - | - | - | 3.33 A | - | - | - | - | - | 120W | ITE (Commercial) | 4.242 kV | 80% | 0°C ~ 70°C (With Derating) | PFC, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.28" H (127.0mm x 76.2mm x 32.5mm) | CB Scheme, EN, IEC, SIQ, TUV, UL | 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3 |
|
|
|
EPL225 (225W) |
Box |
Active | Open Frame | 1 | 85 ~ 264 VAC | 28V | - | - | - | - | - | 5.36 A | - | - | - | - | - | 150W (225W Forced Air) | ITE (Commercial), Medical | 4 kV | 93% | -20°C ~ 70°C (With Derating) | PFC, Standby Output, Universal Input | Chassis Mount | 4.00" L x 2.00" W x 1.26" H (101.6mm x 50.8mm x 32.3mm) | CB, CE, UL | 62368-1 |
|
|
|
CINT1200 (200W) |
Bulk |
Not For New Designs | Open Frame | 1 | 90 ~ 264 VAC | 24V | - | - | - | - | - | 7.5 A | - | - | - | - | - | 180W (200W Forced Air) | ITE (Commercial) | 4 kV | 88% | -10°C ~ 70°C | DC Input Capable, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.30" H (127.0mm x 76.2mm x 31.8mm) | CE | - |
|
|
|
CINT1200 (200W) |
Bulk |
Not For New Designs | Open Frame | 1 | 90 ~ 264 VAC | 12V | - | - | - | - | - | 15 A | - | - | - | - | - | 180W (200W Forced Air) | ITE (Commercial) | 4 kV | 88% | -10°C ~ 70°C | DC Input Capable, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.30" H (127.0mm x 76.2mm x 31.8mm) | CE | - |
|
|
|
CINT1200 (200W) |
Bulk |
Not For New Designs | Open Frame | 1 | 90 ~ 264 VAC | 48V | - | - | - | - | - | 3.75 A | - | - | - | - | - | 180W (200W Forced Air) | ITE (Commercial) | 4 kV | 88% | -10°C ~ 70°C | DC Input Capable, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.30" H (127.0mm x 76.2mm x 31.8mm) | CE | - |
|
|
|
ECM (100W) |
Box |
Active | Open Frame | 1 | 90 ~ 264 VAC, 120 ~ 370 VDC | 33V | - | - | - | - | - | 3 A | - | - | - | - | - | 100W | ITE (Commercial), Medical | 4 kV | 80% | 0°C ~ 70°C (With Derating) | Adjustable Output, Universal Input | Chassis Mount | 4.50" L x 2.50" W x 1.20" H (114.3mm x 63.5mm x 30.5mm) | CB, CE | 62368-1 |
|
|
|
MINT1180 (180W) |
Bulk |
Not For New Designs | Open Frame | 1 | 100 ~ 240 VAC | 24V | - | - | - | - | - | 7.5 A | - | - | - | - | - | 180W | Medical | 4 kV | 88% | -10°C ~ 70°C (With Derating) | Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.30" H (127.0mm x 76.2mm x 31.8mm) | CE | - |
|
|
|
VSBU-120-D (120W) |
Box |
Not For New Designs | Open Frame | 2 | 90 ~ 260 VAC | 5V | 12V | - | - | - | - | 15 A | 6 A | - | - | - | - | 120W | ITE (Commercial) | 4.242 kV | 80% | 0°C ~ 70°C (With Derating) | PFC, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.28" H (127.0mm x 76.2mm x 32.5mm) | CB Scheme, EN, IEC, SIQ, TUV, UL | 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3 |
|
|
|
Linear BB |
Bulk |
Active | Linear | 2 | 100, 120, 220, 230, 240 VAC | 15V | -15V | - | - | - | - | 1.5 A | 1.5 A | - | - | - | - | 41W | ITE (Commercial) | 4.242 kV | 55% | 0°C ~ 50°C | Adjustable Output, Remote Sense | Chassis Mount | 7.00" L x 4.87" W x 2.95" H (177.8mm x 123.7mm x 74.9mm) | CE, CSA, UL | 60950-1; 62368-1 |
|
|
|
VSBU-120-D (120W) |
Box |
Not For New Designs | Open Frame | 2 | 90 ~ 260 VAC | 5V | 24V | - | - | - | - | 15 A | 3.5 A | - | - | - | - | 120W | ITE (Commercial) | 4.242 kV | 80% | 0°C ~ 70°C (With Derating) | PFC, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.28" H (127.0mm x 76.2mm x 32.5mm) | CB Scheme, EN, IEC, SIQ, TUV, UL | 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3 |
|
|
|
LPQ200-M (200W) |
Tray |
Active | Open Frame | 4 | 90 ~ 264 VAC | 3.3V | 5V | 12V | -12V | - | - | 13 A | 13 A | 5 A | 1 A | - | - | 100W (200W Forced Air) | ITE (Commercial), Medical | - | 84% | 0°C ~ 70°C (With Derating) | Adjustable Output, DC Input Capable, Remote Sense, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.32" H (127.0mm x 76.2mm x 33.5mm) | CB, CE | - |
|
|
|
SMP350 (350W) |
Box |
Active | Enclosed | 1 | 85 ~ 264 VAC | 12V | - | - | - | - | - | 25 A | - | - | - | - | - | 300W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 70°C (With Derating) | Remote On/Off | Chassis Mount | 7.00" L x 3.60" W x 1.70" H (177.8mm x 91.4mm x 43.2mm) | CB, CE, TUV, UL | 62368-1 |
|
|
|
VMS-160 (160W) |
Tray |
Active | Open Frame | 1 | 85 ~ 264 VAC, 125 ~ 373 VDC | 12V | - | - | - | - | - | 8.33 A | - | - | - | - | - | 100W (160W Forced Air) | Medical | 5.656 kV | 90% | -25°C ~ 70°C (With Derating) | Adjustable Output, PFC, Standby Output, Universal Input | Chassis Mount | 4.00" L x 2.00" W x 0.85" H (101.6mm x 50.8mm x 21.6mm) | CB Scheme, EN, IEC, SIQ, TUV, UL | 55024; 60601-1; 60950-1; 61000-3-2; 61000-3-3 |
|
|
|
VMS-160 (160W) |
Tray |
Active | Open Frame | 1 | 85 ~ 264 VAC, 125 ~ 373 VDC | 24V | - | - | - | - | - | 4.17 A | - | - | - | - | - | 100W (160W Forced Air) | Medical | 5.656 kV | 90% | -25°C ~ 70°C (With Derating) | Adjustable Output, PFC, Standby Output, Universal Input | Chassis Mount | 4.00" L x 2.00" W x 0.85" H (101.6mm x 50.8mm x 21.6mm) | CB Scheme, EN, IEC, SIQ, TUV, UL | 55024; 60601-1; 60950-1; 61000-3-2; 61000-3-3 |
|
|
|
Linear N |
Bulk |
Active | Linear | 1 | 100, 120, 220, 230, 240 VAC | 12V | - | - | - | - | - | 5.1 A | - | - | - | - | - | 61W | ITE (Commercial) | 4.242 kV | 55% | 0°C ~ 50°C | Adjustable Output, Remote Sense | Chassis Mount | 7.00" L x 4.87" W x 3.28" H (177.8mm x 123.7mm x 83.3mm) | CE, CSA, UL | 60950-1; 62368-1 |