PDF |
Mfr Part # |
RFQ |
Series |
Packaging |
Product Status | Type | Number of Outputs | Voltage - Input | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Current - Output 1 | Current - Output 2 | Current - Output 3 | Current - Output 4 | Current - Output 5 | Current - Output 6 | Power (Watts) | Applications | Voltage - Isolation | Efficiency | Operating Temperature | Features | Mounting Type | Size / Dimension | Approval Agency | Standard Number |
|
|
|
LCW25 (25W) |
Box |
Active | Enclosed | 1 | 85 ~ 305 VAC, 100 ~ 430 VDC | 5V | - | - | - | - | - | 5 A | - | - | - | - | - | 25W | ITE (Commercial), Industrial | 4 kV | 81% | -30°C ~ 70°C (With Derating) | Adjustable Output, DC Input Capable | Chassis Mount | 3.70" L x 2.17" W x 0.98" H (94.0mm x 55.0mm x 25.0mm) | CE, EN, UKCA, UL | 62368-1 |
|
|
|
LCS75 (75W) |
Box |
Active | Enclosed | 1 | 85 ~ 264 VAC, 120 ~ 373 VDC | 24V | - | - | - | - | - | 3.2 A | - | - | - | - | - | 77W | Household Appliances, ITE (Commercial), Industrial | 4 kV | 90% | -30°C ~ 70°C (With Derating) | Adjustable Output, Universal Input | Chassis Mount | 3.90" L x 3.23" W x 1.18" H (99.0mm x 82.0mm x 30.0mm) | CE, TUV, UL | 62368-1 |
|
|
|
LCS100 (100W) |
Box |
Active | Enclosed | 1 | 85 ~ 264 VAC, 120 ~ 373 VDC | 12V | - | - | - | - | - | 8.5 A | - | - | - | - | - | 102W | Household Appliances, ITE (Commercial), Industrial | 4 kV | 87% | -30°C ~ 70°C (With Derating) | Adjustable Output, Universal Input | Chassis Mount | 5.08" L x 3.82" W x 1.18" H (129.0mm x 97.0mm x 30.0mm) | CE, TUV, UL | 62368-1 |
|
|
|
MDS-040 (40W) |
Box |
Active | Open Frame | 1 | 90 ~ 264 VAC | 12V | - | - | - | - | - | 3.3 A | - | - | - | - | - | 40W | ITE (Commercial), Medical | 4 kV | 84% | -10°C ~ 70°C | Standby Output, Universal Input | Chassis Mount | 3.00" L x 2.00" W x 0.90" H (76.2mm x 50.8mm x 22.9mm) | CB Scheme, CE, EN, UL | 50581; 55011; 55032; 60601-1; 60950-1 |
|
|
|
CFM20 (20W) |
Box |
Active | Open Frame | 1 | 85 ~ 264 VAC | 24V | - | - | - | - | - | 920 mA | - | - | - | - | - | 22W | ITE (Commercial) | 4.242 kV | 81% | 0°C ~ 70°C (With Derating) | Universal Input | Chassis Mount | 3.50" L x 2.00" W x 0.91" H (88.9mm x 50.8mm x 23.0mm) | CE, cURus, TUV | - |
|
|
|
FCS60 (60W) |
Box |
Active | Open Frame | 1 | 80 ~ 264 VAC | 12V | - | - | - | - | - | 5 A | - | - | - | - | - | 60W | Household Appliances, ITE (Commercial), Medical | 4 kV | 85% | -25°C ~ 70°C (With Derating) | Adjustable Output, Universal Input | Chassis Mount | 4.00" L x 2.00" W x 1.10" H (101.6mm x 50.8mm x 27.9mm) | CE | 62368-1 |
|
|
|
VGS-100W (100W) |
Box |
Active | Enclosed | 1 | 85 ~ 305 VAC, 120 ~ 431 VDC | 24V | - | - | - | - | - | 4.5 A | - | - | - | - | - | 108W | Household Appliances, ITE (Commercial) | 4 kV | 89.5% | -30°C ~ 70°C (With Derating) | - | Chassis Mount | 5.08" L x 3.82" W x 1.18" H (129.0mm x 97.0mm x 30.0mm) | CE, cURus | 60335-1; 62368-1 |
|
|
|
PMT (50W) |
Bulk |
Active | Enclosed | 1 | 85 ~ 264 VAC | 24V | - | - | - | - | - | 2.09 A | - | - | - | - | - | 50W | ITE (Commercial) | 3 kV | 86% | -10°C ~ 70°C (With Derating) | Adjustable Output, Universal Input | Chassis Mount | 3.86" L x 3.86" W x 1.50" H (98.0mm x 98.0mm x 38.0mm) | CB, CCC, CE, cURus, TUVgs | - |
|
|
|
MDS-065 (65W) |
Box |
Active | Open Frame | 1 | 90 ~ 264 VAC | 18V | - | - | - | - | - | 3.6 A | - | - | - | - | - | 65W | ITE (Commercial), Medical | 4 kV | 85% | -10°C ~ 70°C | Standby Output, Universal Input | Chassis Mount | 4.00" L x 2.00" W x 1.20" H (101.6mm x 50.8mm x 30.5mm) | CB Scheme, CE, CQC, EN, UL | 50581; 55011; 55032; 60601-1; 60950-1 |
|
|
|
VCS (50W) |
Box |
Active | Enclosed | 1 | 85 ~ 264 VAC | 15V | - | - | - | - | - | 3.3 A | - | - | - | - | - | 50W | ITE (Commercial) | 3 kV | 86% | -25°C ~ 70°C (With Derating) | Adjustable Output, DC Input Capable, Universal Input | Chassis Mount | 4.35" L x 3.07" W x 1.38" H (110.5mm x 78.0mm x 35.0mm) | CB | 62368-1 |
|
|
|
CFM60S (60W) |
Box |
Active | Open Frame | 1 | 90 ~ 264 VAC | 24V | - | - | - | - | - | 2.5 A | - | - | - | - | - | 60W | ITE (Commercial) | 4.242 kV | 86% | 0°C ~ 70°C (With Derating) | Universal Input | Chassis Mount | 4.00" L x 2.00" W x 1.20" H (101.6mm x 50.8mm x 30.5mm) | CE, cURus, FCC, TUV | - |
|
|
|
LOF120-20Bxx (120W) |
Tray |
Active | Open Frame | 1 | 85 ~ 264 VAC, 120 ~ 370 VDC | 24V | - | - | - | - | - | 5 A | - | - | - | - | - | 120W | Household Appliances, ITE (Commercial), Medical | 4 kV | 95% | -40°C ~ 85°C (With Derating) | Adjustable Output, PFC, Standby Output, Universal Input | Chassis Mount | 3.00" L x 2.00" W x 1.22" H (76.2mm x 50.8mm x 31.0mm) | CE, cURus | 60335-1; 60601-1; 62368-1 |
|
|
|
LOF120-20Bxx (120W) |
Tray |
Active | Open Frame | 1 | 85 ~ 264 VAC, 120 ~ 370 VDC | 12V | - | - | - | - | - | 9.5 A | - | - | - | - | - | 114W | Household Appliances, ITE (Commercial), Medical | 4 kV | 94% | -40°C ~ 85°C (With Derating) | Adjustable Output, PFC, Standby Output, Universal Input | Chassis Mount | 3.00" L x 2.00" W x 1.22" H (76.2mm x 50.8mm x 31.0mm) | CE, cURus | 60335-1; 60601-1; 62368-1 |
|
|
|
LS (75W) |
Bulk |
Active | Enclosed | 1 | 88 ~ 264 VAC | 15V | - | - | - | - | - | 5 A | - | - | - | - | - | 75W | ITE (Commercial) | 3 kV | 85% | -25°C ~ 70°C (With Derating) | Adjustable Output, DC Input Capable, Universal Input | Chassis Mount | 5.10" L x 3.80" W x 1.50" H (129.5mm x 96.5mm x 38.1mm) | CE | - |
|
|
|
MTA040 (40W) |
Bulk |
Active | Open Frame | 1 | 85 ~ 264 VAC | 12V | - | - | - | - | - | 3.3 A | - | - | - | - | - | 40W | Medical | - | 87% | -20°C ~ 70°C (With Derating) | Universal Input | Chassis Mount | 4.00" L x 2.00" W x 1.08" H (101.6mm x 50.8mm x 27.5mm) | CB, CE, cTUVus | - |
|
|
|
VOF-85B (85W) |
Box |
Active | Open Frame | 1 | 90 ~ 264 VAC | 24V | - | - | - | - | - | 3.55 A | - | - | - | - | - | 85W | ITE (Commercial) | 3 kV | 89% | -20°C ~ 70°C (With Derating) | Universal Input | Chassis Mount | 4.00" L x 2.00" W x 1.24" H (101.6mm x 50.8mm x 31.6mm) | CB Scheme, CE, EN, FCC, IEC, SIQ, TUV, UL | 55024; 55032 Class B; 61000-3-2; 61000-3-3; 62368-1 |
|
|
|
PMC (100W) |
Box |
Last Time Buy | Enclosed | 1 | 85 ~ 264 VAC | 24V | - | - | - | - | - | 4.17 A | - | - | - | - | - | 100W | ITE (Commercial) | 3 kV | 86% | -20°C ~ 70°C (With Derating) | Adjustable Output, DC Input Capable, Universal Input | Chassis Mount | 6.22" L x 3.82" W x 1.50" H (158.0mm x 97.0mm x 38.0mm) | CB, CCC, CE, cURus, Nemko | - |
|
|
|
ECS (25W) |
Box |
Active | Open Frame | 1 | 80 ~ 264 VAC | 12V | - | - | - | - | - | 2.08 A | - | - | - | - | - | 25W | ITE (Commercial), Medical | 4 kV | 90% | -20°C ~ 70°C (With Derating) | Adjustable Output, DC Input Capable, Universal Input | Chassis Mount | 3.00" L x 2.00" W x 0.95" H (76.2mm x 50.8mm x 24.2mm) | CB | 62368-1 |
|
|
|
LS (100W) |
Bulk |
Active | Enclosed | 1 | 88 ~ 264 VAC | 15V | - | - | - | - | - | 7 A | - | - | - | - | - | 100W | ITE (Commercial) | 3 kV | 84% | -25°C ~ 70°C (With Derating) | Adjustable Output, DC Input Capable, Universal Input | Chassis Mount | 6.30" L x 3.80" W x 1.50" H (160.0mm x 96.5mm x 38.1mm) | CE | - |
|
|
|
PMC (150W) |
Bulk |
Last Time Buy | Enclosed | 1 | 85 ~ 264 VAC | 24V | - | - | - | - | - | 6.25 A | - | - | - | - | - | 150W | ITE (Commercial) | 3 kV | 86% | -20°C ~ 70°C (With Derating) | Adjustable Output, DC Input Capable, Universal Input | Chassis Mount | 7.01" L x 3.82" W x 1.50" H (178.0mm x 97.0mm x 38.0mm) | CCC, CE, cURus | - |