PDF |
Mfr Part # |
RFQ |
Series |
Packaging |
Product Status | Type | Number of Outputs | Voltage - Input | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Current - Output 1 | Current - Output 2 | Current - Output 3 | Current - Output 4 | Current - Output 5 | Current - Output 6 | Power (Watts) | Applications | Voltage - Isolation | Efficiency | Operating Temperature | Features | Mounting Type | Size / Dimension | Approval Agency | Standard Number |
|
|
|
VOF-85 (85W) |
Box |
Active | Open Frame | 1 | 90 ~ 277 VAC | 12V | - | - | - | - | - | 7.1 A | - | - | - | - | - | 85W | ITE (Commercial) | 3 kV | 86% | -20°C ~ 60°C (With Derating) | Adjustable Output, Universal Input | Chassis Mount | 4.00" L x 2.00" W x 1.32" H (101.6mm x 50.8mm x 33.6mm) | CB Scheme, EN, FCC, IEC, SIQ, TUV, UL | 55024; 60950-1; 61000-3-2; 61000-3-3; 61000-6-1; 61000-6-3; 61204-3 |
|
|
|
305RAC / LMF-23B |
Box |
Active | Enclosed | 1 | 85 ~ 305 VAC, 120 ~ 430 VDC | 24V | - | - | - | - | - | 6.3 A | - | - | - | - | - | 151W | Household Appliances, ITE (Commercial) | 4 kV | 87% | -30°C ~ 70°C (With Derating) | Adjustable Output, PFC, Remote On/Off, Universal Input | Chassis Mount | 7.05" L x 3.90" W x 1.18" H (179.0mm x 99.0mm x 30.0mm) | CB, CCC, CE, cURus, UL | 60335-1; 62368-1 |
|
|
|
FSP200-P35 A (200W) |
Box |
Active | Open Frame | 1 | 90 ~ 264 VAC | 12V | - | - | - | - | - | 12.5 A | - | - | - | - | - | 150W (200W Forced Air) | ITE (Commercial) | 500 V | 90% | -20°C ~ 70°C (With Derating) | PFC, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.10" H (127.0mm x 76.2mm x 28.0mm) | CB, CE, cURus, CSA, FCC, UL, VCCI | 60950-1; 62368-1 |
|
|
|
FSP200-P35 (200W) |
Box |
Active | Open Frame | 1 | 90 ~ 264 VAC | 18V | - | - | - | - | - | 8.33 A | - | - | - | - | - | 150W (200W Forced Air) | ITE (Commercial) | 500 V | 91% | -20°C ~ 70°C (With Derating) | PFC, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.10" H (127.0mm x 76.2mm x 28.0mm) | CB, CE, cCSAus, UL | 60950-1; 62368-1 |
|
|
|
ECP (40W) |
Bulk |
Active | Open Frame | 1 | 85 ~ 264 VAC | 18V | - | - | - | - | - | 2.22 A | - | - | - | - | - | 40W | ITE (Commercial), Medical | 4000 V | 90% | -10°C ~ 70°C (With Derating) | PFC, Universal Input | Chassis Mount | 3.00" L x 2.00" W x 0.91" H (76.2mm x 50.8mm x 23.1mm) | - | 62368-1 |
|
|
|
305RAC / LMF-23B |
Box |
Active | Enclosed | 1 | 85 ~ 305 VAC, 120 ~ 430 VDC | 24V | - | - | - | - | - | 8.4 A | - | - | - | - | - | 202W | Household Appliances, ITE (Commercial) | 4 kV | 90% | -30°C ~ 70°C (With Derating) | Adjustable Output, PFC, Remote On/Off, Universal Input | Chassis Mount | 7.05" L x 3.90" W x 1.18" H (179.0mm x 99.0mm x 30.0mm) | CCC, CE, cURus, UL | 60335-1; 62368-1 |
|
|
|
305RAC / LMF-23B |
Box |
Active | Enclosed | 1 | 85 ~ 305 VAC, 120 ~ 430 VDC | 12V | - | - | - | - | - | 16.7 A | - | - | - | - | - | 200W | Household Appliances, ITE (Commercial) | 4 kV | 88% | -30°C ~ 70°C (With Derating) | Adjustable Output, PFC, Remote On/Off, Universal Input | Chassis Mount | 7.05" L x 3.90" W x 1.18" H (179.0mm x 99.0mm x 30.0mm) | CCC, CE, cURus, UL | 60335-1; 62368-1 |
|
|
|
LOF225-20Bxx (225W) |
Tray |
Active | Open Frame | 1 | 85 ~ 264 VAC, 120 ~ 370 VDC | 12V | - | - | - | - | - | 11.67 A | - | - | - | - | - | 140W | Household Appliances, ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 70°C (With Derating) | Adjustable Output, PFC, Standby Output, Universal Input | Chassis Mount | 4.00" L x 2.00" W x 1.00" H (101.6mm x 50.8mm x 25.4mm) | CE, cURus | 60335-1; 60601-1; 62368-1 |
|
|
|
LOF225-20Bxx (225W) |
Tray |
Active | Open Frame | 1 | 85 ~ 264 VAC, 120 ~ 370 VDC | 48V | - | - | - | - | - | 2.91 A | - | - | - | - | - | 140W | Household Appliances, ITE (Commercial), Medical | 4 kV | 94% | -40°C ~ 70°C (With Derating) | Adjustable Output, PFC, Standby Output, Universal Input | Chassis Mount | 4.00" L x 2.00" W x 1.00" H (101.6mm x 50.8mm x 25.4mm) | CE, cURus | 60335-1; 60601-1; 62368-1 |
|
|
|
LOF225-20Bxx (225W) |
Tray |
Active | Open Frame | 1 | 85 ~ 264 VAC, 120 ~ 370 VDC | 27V | - | - | - | - | - | 4.81 A | - | - | - | - | - | 130W | Household Appliances, ITE (Commercial), Medical | 4 kV | 94% | -40°C ~ 70°C (With Derating) | Adjustable Output, PFC, Standby Output, Universal Input | Chassis Mount | 4.00" L x 2.00" W x 1.00" H (101.6mm x 50.8mm x 25.4mm) | CE, cURus | 60335-1; 60601-1; 62368-1 |
|
|
|
FSP250-2F47-B54H (250W) |
Box |
Active | Open Frame | 2 | 90 ~ 264 VAC | 54V | 12V | - | - | - | - | 2.78 A | 8.33 A | - | - | - | - | 250W | ITE (Commercial) | - | 89% | -20°C ~ 70°C (With Derating) | Universal Input | Chassis Mount | 7.50" L x 4.00" W x 1.38" H (190.5mm x 101.6mm x 35.1mm) | CB, FCC, VCCI | - |
|
|
|
FSP250-2F47-A54H (250W) |
Box |
Active | Open Frame | 2 | 90 ~ 264 VAC | 54V | 12V | - | - | - | - | 3.7 A | 4.2 A | - | - | - | - | 250W | ITE (Commercial) | - | 92% | 0°C ~ 70°C (With Derating) | PFC, Universal Input | Chassis Mount | 7.50" L x 4.00" W x 1.38" H (190.5mm x 101.6mm x 35.1mm) | CE, cURus, CSA, FCC, VCCI | 60950-1 |
|
|
|
GRN-60 (60W) |
Box |
Active | Open Frame | 1 | 85 ~ 264 VAC | 15V | - | - | - | - | - | 4 A | - | - | - | - | - | 60W | ITE (Commercial), Medical | - | 87% | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 3.00" L x 2.00" W x 0.83" H (76.2mm x 50.8mm x 21.1mm) | CE, cURus, TUV, UKCA | 60601-1; 62368-1 |
|
|
|
GRN-60 (60W) |
Box |
Active | Open Frame | 1 | 85 ~ 264 VAC | 12V | - | - | - | - | - | 5 A | - | - | - | - | - | 60W | ITE (Commercial), Medical | - | 87% | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 3.00" L x 2.00" W x 0.83" H (76.2mm x 50.8mm x 21.1mm) | CE, cURus, TUV, UKCA | 60601-1; 62368-1 |
|
|
|
GRN-60 (60W) |
Box |
Active | Open Frame | 1 | 85 ~ 264 VAC | 19V | - | - | - | - | - | 3.1 A | - | - | - | - | - | 60W | ITE (Commercial), Medical | - | 87% | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 3.00" L x 2.00" W x 0.83" H (76.2mm x 50.8mm x 21.1mm) | CE, cURus, TUV, UKCA | 60601-1; 62368-1 |
|
|
|
GRN-60 (60W) |
Box |
Active | Open Frame | 1 | 85 ~ 264 VAC | 28V | - | - | - | - | - | 2.2 A | - | - | - | - | - | 60W | ITE (Commercial), Medical | - | 87% | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 3.00" L x 2.00" W x 0.83" H (76.2mm x 50.8mm x 21.1mm) | CE, cURus, TUV, UKCA | 60601-1; 62368-1 |
|
|
|
GRN-60 (60W) |
Box |
Active | Open Frame | 1 | 85 ~ 264 VAC | 5V | - | - | - | - | - | 9 A | - | - | - | - | - | 60W | ITE (Commercial), Medical | - | 85% | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 3.00" L x 2.00" W x 0.83" H (76.2mm x 50.8mm x 21.1mm) | CE, cURus, TUV, UKCA | 60601-1; 62368-1 |
|
|
|
GRN-60 (60W) |
Box |
Active | Chassis | 1 | 85 ~ 264 VAC | 24V | - | - | - | - | - | 2.5 A | - | - | - | - | - | 60W | ITE (Commercial), Medical | - | 87% | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 3.20" L x 2.43" W x 1.28" H (81.3mm x 61.7mm x 32.5mm) | CE, cURus, TUV, UKCA | 60601-1; 62368-1 |
|
|
|
GRN-60 (60W) |
Box |
Active | Chassis | 1 | 85 ~ 264 VAC | 28V | - | - | - | - | - | 2.2 A | - | - | - | - | - | 60W | ITE (Commercial), Medical | - | 87% | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 3.20" L x 2.43" W x 1.28" H (81.3mm x 61.7mm x 32.5mm) | CE, cURus, TUV, UKCA | 60601-1; 62368-1 |
|
|
|
GRN-60 (60W) |
Box |
Active | Chassis | 1 | 85 ~ 264 VAC | 5V | - | - | - | - | - | 9 A | - | - | - | - | - | 45W | ITE (Commercial), Medical | - | 85% | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 3.20" L x 2.43" W x 1.28" H (81.3mm x 61.7mm x 32.5mm) | CE, cURus, TUV, UKCA | 60601-1; 62368-1 |