CPCO-2000-160-BP5

CPCO-2000-160-BP5

Images are for reference only
See Product Specifications

CPCO-2000-160-BP5
Description:
DC-AC CURRENT PROBE, CLAMP-ON, 2
Package:
Box
Datasheet:
CPCO-2000-160-BP5 Datasheet (PDF)
ECAD Model:
-
Product Attributes
Part Number:CPCO-2000-160-BP5
Category:Sensors, Transducers
Subcategory:Current Sensors
Manufacturer:GMW Associates
Packaging:Box
Product Status:Active
For Measuring:AC/DC
Sensor Type:Open Loop
Current - Sensing:2000A
Number of Channels:1
Output:Ratiometric, ±5V
Sensitivity:-
Frequency:DC ~ 40kHz
Linearity:±0.5%
Accuracy:1%
Voltage - Supply:11V ~ 31V
Response Time:10µs
Current - Supply (Max):80mA
Operating Temperature:-40°C ~ 100°C
Polarization:Bidirectional
Mounting Type:Panel Mount
Package / Case:Box
Supplier Device Package:-
In Stock: 10
Stock:
10 Can Ship Immediately
  • Share:
For Use With
CPCO-8000-77-MA
CPCO-8000-77-MA
GMW Associates
DC-AC CURRENT PROBE, CLAMP-ON, 8
F02P015S05L
F02P015S05L
Tamura
SENSOR
L34S600D15T
L34S600D15T
Tamura
CURRENT SENSOR (600A; 15V)
20310200101
20310200101
HARTING
SENSOR CURRENT HALL 200A AC
L07P030D15S
L07P030D15S
Tamura
SENSOR CURRENT HALL
CSNE151-104
CSNE151-104
Honeywell Sensing and Productivity Solutions
SENSOR CURRENT HALL 56A AC/DC
HAC100-S
HAC100-S
LEM USA Inc.
SENSOR CURRENT HALL 100A AC/DC
CR4420-10
CR4420-10
CR Magnetics Inc.
SENSOR CURRENT XFMR 10A AC
CR4450-20
CR4450-20
CR Magnetics Inc.
SENSOR CURRENT XFMR 20A AC
CR4450-150
CR4450-150
CR Magnetics Inc.
SENSOR CURRENT XFMR 15A AC
MLX91206LDC-CAL-003-RE
MLX91206LDC-CAL-003-RE
Melexis Technologies NV
SENSOR CURRENT HALL 10MT AC/DC
20311008102
20311008102
HARTING
CURRENT SENSOR
You May Also Be Interested In
17900-2212-1-8M
17900-2212-1-8M
GMW Associates
CABLE ADAPTER WITH SIGNAL ISOLAT
CPCO-1000-77-BP5
CPCO-1000-77-BP5
GMW Associates
DC-AC CURRENT PROBE, CLAMP-ON, 1
CPCO-4000-77-MA
CPCO-4000-77-MA
GMW Associates
DC-AC CURRENT PROBE, CLAMP-ON, 4
CPCO-12000-77-RMS
CPCO-12000-77-RMS
GMW Associates
DC-AC CURRENT PROBE, CLAMP-ON, 1
CPCO-8000-77-BP10
CPCO-8000-77-BP10
GMW Associates
DC-AC CURRENT PROBE, CLAMP-ON, 8
CPCO-2000-160-BP5
CPCO-2000-160-BP5
GMW Associates
DC-AC CURRENT PROBE, CLAMP-ON, 2
CPCO-4000-160-SE
CPCO-4000-160-SE
GMW Associates
DC-AC CURRENT PROBE, CLAMP-ON, 4
CPCO-1000-160-RMS
CPCO-1000-160-RMS
GMW Associates
DC-AC CURRENT PROBE, CLAMP-ON, 1
CPCO-1000-160-BP10
CPCO-1000-160-BP10
GMW Associates
DC-AC CURRENT PROBE, CLAMP-ON, 1
CPCO-2000-160-BP10
CPCO-2000-160-BP10
GMW Associates
DC-AC CURRENT PROBE, CLAMP-ON, 2
CPCO-16000-160-SE
CPCO-16000-160-SE
GMW Associates
DC-AC CURRENT PROBE, CLAMP-ON, 1
CPCO-2000-77-MA
CPCO-2000-77-MA
GMW Associates
DC-AC CURRENT PROBE, CLAMP-ON, 2